Skip to main content

A NEW CALIBRATION FACILITY FOR DYNAMIC FORCES UP TO 10 kN

Rolf Kumme

Abstract

Dynamic forces realised by accelerated load masses are traceable to acceleration and mass according to the force definition. For the extension of the dynamic force range a new facility based on an electrodynamic shaker system is developed.

Keywords
Dynamic force, Electrodynamic shaker, Air bearings, Calibration
Download
PWC-2003-TC3-013.pdf
DOI
-
IMEKO TC
TC3 - Measurement of Force, Mass, Torque, and Gravity

Event details

Event
XVII IMEKO World Congress
Place
Dubrovnik, CROATIA
Time
22 June 2003 - 28 June 2003
Website
http://www.hmd.hr/imeko/

Back to the proceedings