Skip to main content

Effects of Upstream Butterfly Valve on the Accuracy of a Vortex Flow Meter

E. von Lavante, A. Gedikli, A. Thibaut, S. Tournillon, H. Krisch

Abstract

The problem of accurate determination of volumetric flows by means of vortex-shedding flowmeters in the case of upstream disturbances caused by an butterfly valve, installed 5 diameters upstream of the meter, has been studied. To this end, the flow about the bluff body used in the presently studied vortex-shedding flow meter, having DN25 (simulation) and DN50 (experiments) test sections, was investigated experimentally and numerically.

Keywords
Vortex Flow Meters, Flow Simulation, Experimental Flow Metering, Accuracy, Upstream Disturbance
Download
IMEKO-TC9-2010-018.pdf
DOI
-
IMEKO TC
TC9 - Flow Measurement

Event details

Event
tc9-2010

Back to the proceedings