Skip to main content

Installation Effects of Ultrasonic Flowmeter in Single Bend Pipe

Dan-dan Zheng, Tao Zhang, Li-jun Sun, Tao Meng, He-ming Hu, Chi Wang

Abstract

The downstream flow of 90°single bend was investigated by computational fluid dynamics (CFD). An acoustic transit time flowmeter was exposed to the downstream flow at various positions. Measurement errors with different meter configurations and effects of pipe wall roughness were discussed. Numerical simulation results of three diameter pipes 0.1 m, 1 m and 10 m with increasing the roughness from 0 to 1 mm were presented within Reynolds number (Re) range from 5 × 10<sup>3</sup> to 5 × 10<sup>6</sup>.

Keywords
Ultrasonic flowmeter, Installation effect, Single bend pipe
Download
IMEKO-TC9-2010-087.pdf
DOI
-
IMEKO TC
TC9 - Flow Measurement

Event details

Event
tc9-2010

Back to the proceedings