Skip to main content

ELIMINATION OF UNWANTED VOLTAGE DROPS ACROSS THE LINKS BETWEEN FOUR TERMINAL – PAIR COMPONENTS CONNECTED IN SERIES

Radek Sedláček, Jaroslav Boháček

Abstract

Two possible methods of eliminating unwanted voltage drops in four terminal-pair bridge circuits are discussed, namely employment of combining networks and injection of compensation voltages. As an economical and practical way of producing these voltages, application of a slave digital synthesis (DSS) generator, directly synchronized with the source of the bridge supply voltage, is proposed. A possible design of such a generator, based on employment of a DSP evaluation board, is described.

Keywords
combining network, voltage compensation, phase-locked loop
Download
IMEKO-TC4-2002-117.pdf
DOI
-
IMEKO TC
TC4 - Measurement of Electrical Quantities

Event details

Event
tc4-symp-2002

Back to the proceedings