Redefinition of standard equation for discharge coefficient of throat-tapped flow nozzle
Abstract
Throat-tapped flow nozzle, which is widely used in power plants, are examined for several geometric parameters, throat-tap and upstream-tap diameter, surface roughness of nozzle and so on. It is found that the largest influence factor is the throat-tap diameter. According to the experimental result, new equations for the throat-tapped flow nozzle are proposed. All experimental discharge coefficient is within ±0.5% of the proposed equations.
Event details
- Event
- FLOMEKO 2019
- Technical Committee
- TC9
- flomeko2019@lnec.pt
- Place
- Lisbon, PORTUGAL
- Time
- 26 June 2019 - 28 June 2019
- Website
- http://flomeko2019.lnec.pt