Abstract

A The progressive deployment of Low Power Instrument Transformers in power network for measurement purposes requires studies on their characterization and on the effect of different quantities on their accuracy. In this paper, a fast calibration procedure is introduced. By using a sinc signal, a Low Power Voltage Transformer has been characterized in the power quality frequency range (50 Hz to 2.5 kHz) under the rated voltage conditions.