INTERNAL COMPARISON BETWEEN A REFERENCE TYPE TORQUE CALIBRATION MACHINE AND A 10 N·m DEADWEIGHT TORQUE STANDARD MACHINE
Abstract
A reference torque calibration machine (RTCM) has been developed to validate the calibration of efficient torque transducers. In this study, the calibration and measurement capability (CMC) of the RTCM was evaluated based on the technical guideline. We also compared the RTCM and a 10 N·m deadweight torque standard machine at the National Metrology Institute of Japan (NMIJ) using a torque measuring device with a nominal capacity of 1 N·m.
Event details
- Event
- TC3 Conference 2022
- Technical Committee
- TC3
- imeko2022@fsb.hr
- Place
- Cavtat-Dubrovnik, CROATIA
- Time
- 11 October 2022 - 13 October 2022
- Website
- https://conferences.imeko.org/event/1/