Skip to main content

TORQUE BILATERAL COMPARISON BETWEEN NMISA AND INMETRO

J. Matosse, S. Dlamini, M. Sibisi, R. S. Oliveira, S. P. de Oliveira, J. T. Filho

Abstract

This paper presents the results of a bilateral comparison in torque measurements between NMISA in South Africa and INMETRO in Brazil. For this comparison, NMISA used a 20 kN·m torque comparator machine with a proposed uncertainty of 0.03 % (<i>k</i> = 2) across the entire measuring range. INMETRO used a 3 kN·m lever deadweight standard machine with uncertainty of 0.01 %. The comparison was conducted for both clockwise and counter-clockwise directions. Comparison analysis considered measurement data in the range of 200 N·m to 1 000 N·m. The maximum relative deviation observed for the bilateral is 2 × 10<sup>-4</sup> in both directions.

Keywords
torque; bilateral comparison; comparator machine; relative deviation
Download
IMEKO-TC3-2022-152.pdf
DOI
10.21014/tc3-2022.152
IMEKO TC
TC3 - Measurement of Force, Mass, Torque, and Gravity

Event details

Event
TC3 Conference 2022
Technical Committee
TC3
Email
imeko2022@fsb.hr
Place
Cavtat-Dubrovnik, CROATIA
Time
11 October 2022 - 13 October 2022
Website
https://conferences.imeko.org/event/1/

Back to the proceedings