Skip to main content

Failure limit analysis for Li-ion batteries using Ragone plot: a preliminary study

Mirko Marracci, G. Caposciutti, A. Buffi, G. Bandini and B. Tellini

Abstract

In this paper, a new possible definition of failure zone for Li-ion batteries is proposed. Based on the general concept that a battery can be considered failed when its performance no longer meets the requirements of the application for which it is designed, a new application-dependent failure zone definition is proposed using the Ragone plot of the cell. The results of an experimental campaign to validate the proposal are presented and discussed in the paper.

Keywords
Li-ion batteries; Failure; Ageing
Download
IMEKO-TC10-2022-022.pdf
DOI
10.21014/tc10-2022.022
IMEKO TC
TC10 - Measurement for Diagnostics, Optimization and Control

Event details

Event
TC10 Conference 2022
Technical Committee
TC10
Email
viharos.zsolt@sztaki.mta.hu
Place
Warsaw, POLAND
Time
26 September 2022 - 27 September 2022

Back to the proceedings