Water holdup measurement of oil–water two-phase flow using dual-mode microwave method
Abstract
Water cut is one of the key parameters in the process of oil and gas production. In the present study, wepropose a microwave resonant cavity sensor(MRCS) which can work in both TM010 and TM110 modes, andestablished a water cut measurement of vertical upward oil–water two-phase flow in the range of 0-100 %. The response characteristics of the two resonant modes to water cut are analyzed by the coupling simulation offlow field and electromagnetic field using COMSOL finite element simulation software. A flow experimentisconducted with the designed MRCS measurement system. The sensitivity of the two modes resonantfrequency in different water holdup range is compared. The results show that 95 % of the experimental points’ relative errors is less than ± 5 %.It is indicated that the model can predict water hold with high accuracy, which may provide a solution for wellhead water cut measurement of oil field.
Event details
- Event
- FLOMEKO 2022
- Technical Committee
- TC9
- lich@nim.ac.cn
- Place
- Chongqing, CHINA
- Time
- 1 November 2022 - 4 November 2022
- Website
- http://flomeko2022.msmk.tech/c/index.html