Skip to main content

The City Gas Flow Standard Facility within (2~4) MPa

Han Zhang, Liang Wang, Xinli Dong, Donghong Huang,Peijuan Cao, Yong Li, Ronghui Shang, Shihui Zeng, Xuejian Li

Abstract

In order to meet the traceability requirements of city gas flow meters, the city gas flow standard facility was built based on master meter method. As the non-fixed usage of master meters and the low temperature of natural gas, the uncertainty evaluation and control of the standard facility were investigated. The results showed that the standard facility used four turbine flowmeters as master meters and has mobility, while the achievable flowrate range is within (60 ~ 8600) m³/h and the pressure range of (2 ~ 4) MPa. The uncertainty of the non-point usage of the master meters was controlled based on the curve fitting method, while the uncertainty of the city gas flow standard facility was 0.26 % (k = 2). Compared with NIM-2014, NIM-2015 was more suitable for master meters with scattered error curves. On this basis, the heat transfer model of the cryogenic natural gas flow in pipeline was established. It was found that the dynamic temperature balance of the facility can be achieved through a longer pre-flow time, which can improve the measurement repeatability. The uncertainty of the calibrated flowmeter is 0.32 % (k = 2). In addition, the comparison experiment with NIM verified the above results.

Keywords
City gas; Natural gas flow; Uncertainty evaluation
Download
IMEKO-TC9-2019-071.pdf
DOI
10.21014/tc9-2022.071
IMEKO TC
TC9 - Flow Measurement

Event details

Event
FLOMEKO 2022
Technical Committee
TC9
Email
lich@nim.ac.cn
Place
Chongqing, CHINA
Time
1 November 2022 - 4 November 2022
Website
http://flomeko2022.msmk.tech/c/index.html

Back to the proceedings