Skip to main content

Evaluation of Long-Term Stability of High-Precision Standard for Low-Frequency Voltage Measurement

Oleh Velychko, Valentyn Isaiev

Abstract

The National measuring standards ensure the quality of measurements in different areas of science and technology. The actual errors of standards are not the only necessary characteristics to be determined. The long-term stability of the corrections also should be evaluated to guarantee the uncertainty of measurement is within the specified margin and, as a consequence, the metrological traceability is established. This paper mainly concerns the stability evaluation of the top-level standard for metrology service in low-frequency voltage measurement. The AC-DC transfer difference of high-precision voltage converter has been determined for almost 20 years. The measurements performed gave an opportunity to compare the deviations detected with the relevant combined uncertainties. The long-term stability estimate was within 20 μV/V for the frequency of 1 MHz.

Keywords
longterm stability, highprecision, voltage measurement
Download
IMEKO-TC4-2023-05.pdf
DOI
10.21014/tc4-2023.05
IMEKO TC
TC4 - Measurement of Electrical Quantities

Event details

Event
TC4 Symposium 2023
Technical Committee
TC4
Email
imeko_TC4_2023@senis.swiss
Place
Pordenone, ITALY
Time
20 September 2023 - 21 September 2023
Website
https://conferences.imeko.org/event/3/

Back to the proceedings