Skip to main content

Crosstalk in Gapped-core Contactless Current Sensor

Noby George, Pavel Ripka, Václav Grim

Abstract

A detailed analysis of the crosstalk in the gapped-core current sensor is presented in this paper. The gapped-core current transducer with a magnetic field sensor in the airgap is widely used to measure current in industries and laboratories. We examine the effect of a nearby current-carrying conductor on the performance of the gapped-core transducer, for the first time in this paper. The crosstalk is studied by considering various factors such as angular and linear displacement of the external conductor, core material, and position of the main conductor. A 3D Finite Element Method (FEM) based model is used to analyse the cross talk and results are presented in this paper. This analysis helps the designer to get detailed insight into the effect of the external conductor on the gapped core current transducer.

Keywords
crosstalk, gapped-core, contactless, current sensor
Download
IMEKO-TC4-2023-23.pdf
DOI
10.21014/tc4-2023.23
IMEKO TC
TC4 - Measurement of Electrical Quantities

Event details

Event
TC4 Symposium 2023
Technical Committee
TC4
Email
imeko_TC4_2023@senis.swiss
Place
Pordenone, ITALY
Time
20 September 2023 - 21 September 2023
Website
https://conferences.imeko.org/event/3/

Back to the proceedings