A CONTINUOUS-TIME FIRST ORDER Σ-Δ CONVERTER WITH OFFSET CALIBRATION FOR BIOLOGICAL APPLICATION

F. Borghetti, N. Massari, D. Stoppa, A. Adami, L. Lorenzelli

Abstract

In the present paper, a continuous time Σ?-Δ converter for biological application is presented. The implemented ASIC has been designed for reading piezo-resistive MEMS cantilever used as DNA detector. The readout channel consists of a first analog front-end circuit able to reduce possible input offset and electronic mismatch, followed by a continuous-time 9b first order Σ?-Δ converter for digital conversion. Simulation results show a circuit accuracy on the measurement of resistance variation in the order of 10 ppm within a maximum range of 10%.

Download
IMEKO-IWADC-2011-38.pdf
DOI
-
IMEKO TC
TC4 - Measurement of Electrical Quantities

Event details

Event
IWADC 2011
Technical Committee
TC4
Place
Orvieto, ITALY
Time
30 June 2011 - 1 July 2011
Website
http://www.iwadc2011.diei.unipg.it/Sito/IWADC2011.html

Back to the proceedings