BRADFORD SIMS - CHOKING PRESSURE RATIO GUIDELINES FOR SMALL CFVS

Bradford W. Sims, Michael S. Carter, Charles L. Britton, Robert J. McKee,

Abstract

The ratio of maximum exit static pressure to inlet stagnation pressure that maintains sonic velocity at the throat of a Critical Flow Venturi (CFV) is referred to as the Maximum Back Pressure Ratio (MBPR). Current standards only provide MBPR equations for CFVs operated at throat Reynolds Numbers (Rent) above 200,000. This paper will provide MBPR guidelines for operating CFVs below a Rent of 200,000. Additionally this paper will examine the causes of "premature unchoking" and how diffuser geometry contributes to this effect.

Keywords
sonic, CFVN, Maximum Back Pressure Ratio, MBPR, premature unchoking
Download
IMEKO-TC9-2013-075.pdf
DOI
-
IMEKO TC
TC9 - Flow Measurement

Event details

Event
FLOMEKO 2013
Technical Committee
TC9
Place
Paris, FRANCE
Time
24 September 2013 - 26 September 2013
Website
http://www.flomeko2013.fr