Skip to main content

MEASUREMENT OF FREQUENCY SPECTRUM WITH INTERPOLATED ADAPTIVE CHIRP-Z TRANSFORMATION

Petar Mostarac, Roman Malarić, Goran Petrović

Abstract

In this paper Adaptive Chirp transform (ACT) and Chirp-z transform (CZT) for measurements of frequency spectrum are presented. Algorithms are adjusted according to IEC 61000-4-7 standard. Interpolated ACT with narrowed frequency span is used for Phase Lock Loop (PLL) synchronization. The CZT is used along with windows function, to obtain the amplitudes of signal harmonics and interharmonics. Window function length is defined by PLL. All parts of proposed algorithm are tested through various simulations with changing parameters of analysed signals. This paper shows that CZT can be adjusted to synchronization and measurement of frequency spectrum. Results are comparable to the traditional approach (DFT) and completely satisfy the needs according to standard IEC 61000-4-7.

Keywords
Chirp-Z transformation, interpolated DFT, PLL synchronization, frequency measurement
Download
IMEKO-WC-2015-TC21-407.pdf
DOI
-
IMEKO TC
TC21 - Mathematical Tools for Measurements

Event details

Event
XXI IMEKO World Congress
Place
Prague, CZECH REPUBLIC
Time
30 August 2015 - 4 September 2015
Website
http://imeko2015.org/