Skip to main content

THERMAL Σ-Δ MODULATOR: PERFORMANCE ANALYSIS

L. S. Palma, A. Oliveira, R. C. S. Freire, A. B. Fontes

Abstract

This work presents the system performance analysis, in terms of frequency response and system resolution, of a 1-bit first-order Σ-&Delta thermal modulator. In this system model, some of the operations conversion is performed by the thermoresistive sensor, which operates at constant temperature method. The system performance analysis was realized with a sampled version of the continuous time thermal Σ-&Delta modulator. It will be shown that system performance is dependent on the system oversampling ratio (OSR) and the system transfer function pole and zero which depends on thermal and physical sensor characteristics and system operation conditions. This system was proposed as a solar radiation meter, but it may be applied to fluid velocity measurement.

Keywords
transducer, thermal Σ-&Delta modulation, frequency response, thermoresistive sensor
Download
PWC-2006-TC4-077u.pdf
DOI
-
IMEKO TC
TC4 - Measurement of Electrical Quantities

Event details

Event
XVIII IMEKO World Congress
Place
Rio de Janeiro, BRAZIL
Time
17 September 2006 - 22 September 2006
Website
http://www.metrologia2006.org.br

Back to the proceedings