Skip to main content

Proceedings

9762 papers found

Shi Wei, Zeng Wu, Li Qingzhong

LEEB HARDNESS STANDARD WITH LASER MEASURING

The paper describes the principle, structure and performance of a Leeb Hardness Standard with Laser Measuring (HLSlaser). The range of the standard is (200 ~ 900) HL. At the same time, uncertainty of the standard has been evaluated, of which relative expanded uncertainties ( k = 2) are at range of 1.0% ~ 1.2%. It has been done to make comparison of HL values tested by the standard and by six HL testers made by EQUOTIP Company of Switzerland with 6 HL blocks manufactured by the same company.

XX IMEKO World Congress · TC5 · 2012 · Download
S. Low, K. Hattori, A. Germak, A. Knott

PROPOSED DEFINITION FOR THE BRINELL HARDNESS INDENTATION EDGE

The industrial Brinell hardness test has been in common use for over 100 years. The test is defined by standardized procedures stating that the Brinell hardness number is proportional to the test force divided by the surface area of the indentation. The test procedures require that the surface area be determined by measuring the indentation diameter after removing the test force. This measurement is usually made using an optical microscope, but without having a physical definition of the indentation edge. This paper proposes a physical definition of the indentation edge such that the Brinell...

XX IMEKO World Congress · TC5 · 2012 · Download
L. Ma, S. Low, J. Song

AN APPROACH TO DETERMINING THE BRINELL HARDNESS INDENTATION DIAMETER BASED ON CONTACT POSITION

Significant differences in Brinell hardness results have been observed worldwide largely due to the curved surface at the indentation edge making it difficult to measure its diameter. The indenter/material contact boundary under the test force should be the basis for the Brinell indentation diameter; however, the contact boundary cannot be observed using an optical microscope after the indenter is removed as is required by the test methods. Finite element analysis (FEA) models were used to develop a method to effectively determine the location of the indentation contact boundary after...

XX IMEKO World Congress · TC5 · 2012 · Download
J. Song, S. Low

DEVELOPMENT OF NIST STANDARD REFERENCE METERIAL (SRM) ROCKWELL HARDNESS DIAMOND INDENTERS

The National Institute of Standards and Technology (NIST) is developing Standard Reference Material (SRM) Rockwell Hardness Diamond Indenters to support Rockwell hardness standardization in the U.S. One of the key steps is the geometrical calibration of the SRM indenters. Most tolerances for the geometrical parameters of the SRM indenters are adopted from those of the calibration grade Rockwell diamond indenters specified in the ASTM and ISO standards except for the form deviation from tip radius which was specified with a smaller tolerance of ± 0.8 µm. From the initial calibration results...

XX IMEKO World Congress · TC5 · 2012 · Download
Satoshi Takagi

DETERMINATION OF THE GEOMETRICAL PARAMETERS OF ROCKWELL DIAMOND INDENTERS BY ITERATIVE REGRESSION METHOD

For the verification of Rockwell diamond indenter exactly following the international definition, an iterative method with the least square circle fitting was introduced. This method was applied to the analysis of verification data obtained with a laser probe 3D profile measurement instrument. It was demonstrated that the technique can be used to express the geometrical parameters properly with analytical results as an example. In addition, this technique can be applicable to determine equivalent geometrical parameters obtained with the optical measurement system currently used at NMIJ to...

XX IMEKO World Congress · TC5 · 2012 · Download
Gun-WoongBahng, NaeHyungTak, Seong-Gu Hong, Junhee Hahn

TRACEABILITY IN MEASUREMENT FOR ROCKWELL, BRINELL AND VICKERS HARDNESS

The establishment of traceability in hardness measurement is still under discussion at the ISO TC 164 SC 3 subcommittee on hardness testing. Two paths for establishing traceability are proposed for Rockwell hardness measurement in ISO 6508-1. One way is to take a route to SI units through direct calibration of machine components; the other way is to take a route to the hardness measurement standard through indirect calibration of machine performance. This confusion is partly caused by the characteristics of hardness; i.e., a procedure dependent property. In this paper, methods for the...

XX IMEKO World Congress · TC5 · 2012 · Download
C. Kuzu, C. Oysu, S. Fank, E. Pelit

ESTABLISHMENT OF ROCKWELL HARDNESS SCALES AT UME

A dead weight type Rockwell Hardness Standard Machine with a laser interferometer optic system was established to provide traceability in the field of hardness measurement for Rockwell Hardness scales at UME (National Metrology Institute of Turkey). Traceability of each component constituting Rockwell scales such as force, depth measuring system and testing cycle to national standards was provided by direct calibration. To realize performance tests of the machine as a whole, hardness reference blocks calibrated by PTB were used. In this paper, Rockwell Hardness Standard Machine of TÜBITAK...

XX IMEKO World Congress · TC5 · 2012 · Download
Koichiro Hattori, Akihiro Ota

A ROUND ROBIN TEST OF ROKCWELL B SCALE HARDNESS

A round robin test of Rockwell B scale was carried out among the calibration class laboratories and testing class laboratories in Japan. Block calibration laboratories and general class machines are participated to the round robin test. The common indenter holder is prepared to investigate the indenter holder effect. Indenter ball (Tungsten carbide ball) is also provided and each participant uses the new ball for common and eachlaboratory’s holder, respectively. Blocks used are 30, 60, and 90 HRB and two blocks from different manufacturer is used for each level. The materials of the blocks...

XX IMEKO World Congress · TC5 · 2012 · Download
C.Landi, G. Del Prete, D.Gallo

REAL-TIME SMART METERS NETWORK FOR ENERGY MANAGEMENT

In this paper, an architecture of a low-cost ARMbased Smart Metering network is presented. The system is designed to be suitable for Smart Grids applications aimed to a more efficient energy use according to the article 13 of Directive 2006/32/EC. The network is composed by several slave smart meters that continuously monitor loads and energy generator to make available information in real-time such as power and energy consumption/generation and several power quality parameters to specific master device called data aggregator via CAN bus. This device integrating the information coming from...