Realization of forces (2N-20N) by primary method |
|---|
| Kamlesh K. Jain, S.S.K. Titus, H.N.P. Poddar and S.K. Dhulkhed |
- Abstract:
- The present paper describes the preliminary results of the metrological characterization of the newly design and developed force machine to realize the forces in the range 2N- 20N with an expanded uncertainty of 50 ppm. The characterization of the machine is carried out in compression using two transfer force standards of 5 and 20 Newton capacity. The calibration of the transfer standards directly against the dead weight force machine shows that the repeatability and reproducibility are better than 0.002% and 0.003% respectively, over the full range of measurement.
- Keywords:
- force realization, dead weight force machine, force metrology
- Download:
- IMEKO-TC3-2007-055u.pdf
- DOI:
- -
- Event details
- IMEKO TC:
- TC3
- Event name:
- Cultivating Metrological Knowledge
- Title:
20th Conference on Measurement of Force, Mass and Torque (together with 3rd TC16 Conference on Pressure Measurement & 1st TC22 Conference on Vibration Measurement)
- Place:
- Merida, MEXICO
- Time:
- 27 November 2007 - 01 December 2007