The long-term behaviour of force transducers as a criteria for the selection of new transfer standards

Aimo Pusa
Abstract:
The laboratory of MIKES-Lahti Precision Oy has made over almost twenty years comparisons with the PTB, utilizing more than ten different force transducers. These comparisons have been made regularly every year to supervise the traceability of force. The results of these comparisons are showing different kinds of behaviours. For the traceability the most important characteristic is the stability of the sensitivity. The change of the sensitivity directly influences the measurement uncertainty and as a result affects the final uncertainty of the intercomparison. The second characteristic is the zero reading, which can indicate the change of the measurement behaviour of the transducer.
Keywords:
force transducer, long term stability, force intercomparison
Download:
IMEKO-TC3-2007-057u.pdf
DOI:
-
Event details
IMEKO TC:
TC3
Event name:
Cultivating Metrological Knowledge
Title:

20th Conference on Measurement of Force, Mass and Torque (together with 3rd TC16 Conference on Pressure Measurement & 1st TC22 Conference on Vibration Measurement)

Place:
Merida, MEXICO
Time:
27 November 2007 - 01 December 2007