Abstract:
Two IMGC multicomponent dynamometers were used to measure the parasitic components generated by the APPLUS+ 0,5 MN deadweight force standard machine. Results are presented which indicate that they are of a very low level. Measurements of the dynamic components during weight changes and free suspension of the system are also presented.