CALIBRATION OF HIGH ACCURACY CLASS STANDARD CURRENT TRANSFORMERS

Dragana Naumovic-Vukovic, Slobodan Skundric, Dragan Kovacevic, Srdjan Milosavljevic
Abstract:
Main characteristic of high accuracy class current transformers is very small amplitude and phase errors (approximately 10 ppm). Such an error is a reason of complexity and sensitiveness of that metrological task. This paper presents a new method for high accuracy class current transformers calibration simultaneously with two different measuring apparatus. The method is presented as well as measuring scheme and calibration results. Estimation of uncertainty of measurement shows that this method has better results than separated calibration methods.
Keywords:
current transformers, calibration, uncertainty of measurement
Download:
IMEKO-WC-2009-TC4-318.pdf
DOI:
-
Event details
Event name:
XIX IMEKO World Congress
Title:

Fundamental and Applied Metrology

Place:
Lisbon, PORTUGAL
Time:
06 September 2009 - 11 September 2009