NON-LINEARITY DIAGNOSTICS FOR CONDUCTIVE ADHESIVES

Vaclav Papez, Stanislava Papezova
Abstract:
The level of intermodulation products that are generated represents the extent of non-linearity for any electronic component. To determine the quality of connections with conductive adhesives the technique of evaluating non-linearity was used as a diagnostic method. The used measuring equipment is based on the evaluation of intermodulation distortion, which is generated by the non-linear component, when two sinusoidal signals are supplied. The equipment measures non-linearity of 3 orders. The measured level of non-linearity is -180 dB with respect to the actuating signal. The maximum current of the actuating signal is 2 x 2A, the sensitivity of the indicator is 10 nV.
Download:
IMEKO-TC4-2010-015.pdf
DOI:
-
Event details
IMEKO TC:
TC4
Event name:
Instrumentation for the Information and Communication Technology Era
Title:
XVIIth IMEKO TC4 Symposium & 15th International Workshop on ADC Modelling and Testing (together with 3rd IMEKO TC19 Symposium)
Place:
Kosice, SLOVAKIA
Time:
08 September 2010 - 10 September 2010