Measurements of Passive Components Using of an IEEE 1149.4 Mixed-Signal Test Bus |
|---|
| Bogdan Bartosiński |
- Abstract:
- The paper presents results of investigations on the use of a mixed-signal test bus IEEE 1149.4 for measurements of passive RLC elements placed on electronic circuit boards. In the tests integrated circuits the STA400, the first commercial integrated circuits compliant with the IEEE 1149.4, were used. Measurements were carried out using methods proposed in the IEEE 1149.4 standard as well as newly-developed methods oriented at bus testing. The methodology of measurements and the achieved results are also presented.
- Download:
- IMEKO-TC4-2005-038.pdf
- DOI:
- -
- Event details
- IMEKO TC:
- TC4
- Event name:
- TC4 Workshop 2005
- Title:
10th IMEKO TC4 International Workshop on ADC Modelling and Testing - IWADC (together with XIVth IMEKO TC4 International Symposium on New Technologies in Measurement and Instrumentation)
- Place:
- Gdynia/Jurata, POLAND
- Time:
- 12 September 2005 - 15 September 2005