STATISTICAL METHODS FOR THE HF PRIMARY POWER STANDARD REALIZATION |
|---|
| L. Brunetti, L. Oberto, M. Sellone |
- Abstract:
- A coaxial microcalorimeter based on thermoelectric detection is the system used to realize the broadband primary power standard at high frequency by Istituto Nazionale di Ricerca Metrologica, Italy. The paper describes and compares two analysis methods that can be applied to the measurement data for evaluating the overall system uncertainty. Methods are completely general and we applied them to our measurement system that can operate with 7 mm, 3.5 mm and 2.92 mm coaxial insets, covering, therefore, the frequency range of 10 MHz -40 GHz.
- Keywords:
- Measurement standards, microwave measurements, power measurements, thermoelectric devices, transmission line measurements
- Download:
- IMEKO-TC4-2011-012.pdf
- DOI:
- -
- Event details
- IMEKO TC:
- TC4
- Event name:
- TC4 Symposium 2011
- Title:
XVIIIth IMEKO TC4 International Symposium on Measurement of Electrical Quantities (part of Metrologia2011, together with IX International Congress on Electrical Metrology - IX SEMETRO)
- Place:
- Natal, BRAZIL
- Time:
- 27 September 2011 - 30 September 2011