INMETRO’S PRIMARY AC-DC CURRENT TRANSFER STANDARD BASED ON PMJTCS |
|---|
| R. Afonso, M. Klonz, R. M. Souza, R. P. Landim |
- Abstract:
- This paper describes the new primary standard for the ac-dc current transfer at Inmetro, based on PMJTCs and the new shunts manufactured by Fluke for rated currents from 10 mA up to 20 A. The build-up of the ac-dc current scale is described together with the uncertainty budgets which result in final uncertainties at 5 A of 6 μA/A to 12 μA/A in the frequency range from 10 Hz to 100 kHz. These are small compared to international standards.
- Keywords:
- ac-dc difference, PMJTC, comparison
- Download:
- IMEKO-TC4-2011-049.pdf
- DOI:
- -
- Event details
- IMEKO TC:
- TC4
- Event name:
- TC4 Symposium 2011
- Title:
XVIIIth IMEKO TC4 International Symposium on Measurement of Electrical Quantities (part of Metrologia2011, together with IX International Congress on Electrical Metrology - IX SEMETRO)
- Place:
- Natal, BRAZIL
- Time:
- 27 September 2011 - 30 September 2011