INVESTIGATION ON CALIBRATION OF FUEL ETHANOL FLOW METER |
|---|
| R. Doihara, T. Shimada, N. Furuichi, Y. Terao |
- Abstract:
- Calibrations with ethanol, water and kerosene have been conducted by using a transferable test package which consisted of positive displacement (PD), turbine (TB), Coriolis (CMF) flowmeters and a small volume prover (SVP). Flowmeter performances and establishment a temporary ethanol flow standard have been investigated. It is founded that liquid replacement in the PD and the TB induced transitions of K-factor over several days. Performances of mass and volume flow output of CMF were also evaluated.
- Keywords:
- ethanol, water, kerosene, positive displacement, turbine, Coriolis, small volume prover, standard, K-factor
- Download:
- IMEKO-TC9-2013-019.pdf
- DOI:
- -
- Event details
- IMEKO TC:
- TC9
- Event name:
- FLOMEKO 2013
- Title:
16th International Flow Measurement Conference
- Place:
- Paris, FRANCE
- Time:
- 24 September 2013 - 26 September 2013