ACCURACY ENHANCEMENT OF A COMBINED V/Z CLAMP-ON ULTRASONIC FLOW

Sejong Chun, Byung-Ro Yoon, Woong Kang, Hyu-Sang Kwon
Abstract:
Ultrasonic flow metering with clamp-on type transducers is a promising method when portability in flow metering is necessary. Nevertheless, the clamp-on ultrasonic flow meter has low measurement accuracy as flow speed in the pipe decreases. If the two types of clamp-on ultrasonic flow paths, namely, Z-shaped and V-shaped ultrasonic paths, are combined, measurement accuracy can be increased because the metering output becomes robust. In the present study, the measurement accuracy of the combined clamp-on ultrasonic flow meter was within ±2 % at 50 m3/h, which was smaller than those of the Z-shaped and the V-shaped clamp-on ultrasonic flow meters at the same flow rate. This can provide an advantage for water resource management because a general guideline for the water resource management is less than ±2 %.
Keywords:
clamp-on ultrasonic flow meter, V-shaped, Z-shaped
Download:
IMEKO-TC9-2013-083.pdf
DOI:
-
Event details
IMEKO TC:
TC9
Event name:
FLOMEKO 2013
Title:

16th International Flow Measurement Conference

Place:
Paris, FRANCE
Time: