- Abstract:
- This paper presents new data and shows that the existing drain-hole equation in ISO/TR 15377 is unsatisfactory: it leads to flowrate errors up to nearly 2% in magnitude. The data on drain holes have a surprisingly strong dependence on the circumferential location of the pressure tappings. However, a new analysis takes this into account and has produced a formula for d’, the corrected orifice diameter taking account of the drain hole. It is very desirable to amend ISO/TR 15377:2007.