A NEW CALIBRATION DEVICE FOR SILK SCREEN TENSION METER

Hu Xiaoyin, Yu Yueling, Yu Peiying, Kang Zhangy
Abstract:
In this paper, a calibration device for silk screen tension meter is designed. The device has a measurement range from 5 to 100 N/cm. It can achieve simultaneous loading in x and y directions by servo motors. For loading accuracy, two high precisionforce sensors are utilized in the closed-loop control system for each direction. To verify the device, it is utilized to calibrate a commercial available silk screen tension meter. The results from the device are compared with that from the Swiss Federal Office of Metrology. It demonstrates that the max error is 0.5 %.
Keywords:
silk screen tension meter, calibration device, force, DIN 16611-1990
Download:
IMEKO-TC3-2014-037.pdf
DOI:
-
Event details
IMEKO TC:
TC3
Event name:
TC3 Conference 2014
Title:

22nd Conference on the Measurement of Force, Mass and Torque (together with 3rd TC22 Conference on Vibration Measurement and 12th TC5 Conference on the Measurement of Hardness)

Place:
Cape Town, SOUTH AFRICA
Time:
03 February 2014 - 06 February 2014