Thickness measurements of corroded district heating pipelines with utilization of Structured Light Technique |
|---|
| M. Malesa, I. Mazurkiewicz, A. Lebek, J. Michonski, K. Malowany, M. Kujawinska |
- Abstract:
- In this paper we present application of the Structured Light Illumination method for measurements of thickness of corroded district heating pipelines. The presented methodology allowed determination of the depth of pitting corrosion centres on both inner and outer sides and in each point of the pipe. Obtained data was consequently utilized for statistical analysis of corrosion growth process. The conclusions about the pitting corrosion process, as well as possible development of the presented methodology are discussed in conclusions.
- Download:
- IMEKO-TC10-2014-008.pdf
- DOI:
- -
- Event details
- IMEKO TC:
- TC10
- Event name:
- TC10 Workshop on Technical Diagnostics 2014
- Title:
13th IMEKO TC10 Workshop "Advanced measurement tools in technical diagnostics for systems' reliability and safety"
- Place:
- Warsaw, POLAND
- Time:
- 26 June 2014 - 27 June 2014