Method of Integral Nonlinearity Testing and Correction of Multi-Range ADC by Direct Measurement of Output Voltages of Multi-Resistors Divider |
|---|
| Hu Zhengbing, Kochan Roman, Kochan Orest, Su Jun, Halyna Klym |
- Abstract:
- There is developed method of testing points generation for identification and correction of integral nonlinearity of high performance ADC. The developed method is based on averaging all voltages of multi-resistors voltage divider. It is investigated influence of resistors’ error and random error of ADC on residual error of integral nonlinearity correction for method based on multi-resistor divider.
- Download:
- IMEKO-TC10-2014-013.pdf
- DOI:
- -
- Event details
- IMEKO TC:
- TC10
- Event name:
- TC10 Workshop on Technical Diagnostics 2014
- Title:
13th IMEKO TC10 Workshop "Advanced measurement tools in technical diagnostics for systems' reliability and safety"
- Place:
- Warsaw, POLAND
- Time:
- 26 June 2014 - 27 June 2014