Unconventional double-current circuit – accuracy measures and application in two-parameter measurement

Zygmunt Warsza, Adam Idzkowski, Wojciech Walendziuk
Abstract:
In this paper some interesting and novel features of a four-terminal (4T) network are presented. A single DC current source is switched over and connected in turns to opposite arms of the four-element bridge circuit. This two-voltage-output circuit is called a double current bridge. The output voltages are dependent on the arm resistance increments and their values are given in absolute and relative units. The accuracy measures (limited errors and standard uncertainties) of two transfer functions are presented. A simple application with two sensors acting as strain gauges and RTD’s is presented. The simplified signal conditioning formulas of two- parameter measurement of strain and temperature of a cantilever beam are discussed. Some results achieved with the use of the circuit are presented.
Download:
IMEKO-TC10-2014-030.pdf
DOI:
-
Event details
IMEKO TC:
TC10
Event name:
TC10 Workshop on Technical Diagnostics 2014
Title:

13th IMEKO TC10 Workshop "Advanced measurement tools in technical diagnostics for systems' reliability and safety"

Place:
Warsaw, POLAND
Time:
26 June 2014 - 27 June 2014