FLOW MEASUREMENT UNCERTAINTY OF NATURAL GAS METERING STATION IN GAS PROCESSING UNITY |
|---|
| Valmir Ruis, N. M. Taira, José M. Câmara Brito |
- Abstract:
- Orifice plates are the most common flow meters used in Brazil to measure natural gas in metering stations in processing units.
This article presents the results of analysis of the present situation of gas flow metering stations according to metrological and dimensional criteria of AGA Report #3. The uncertainty analysis was made following the guidelines of the ISO Guide for Uncertainty in Measurement (ISO GUM). - Download:
- IMEKO-TC9-2000-071.pdf
- DOI:
- -
- Event details
- IMEKO TC:
- TC9
- Event name:
- FLOMEKO 2000
- Title:
- 10th Conference on Flow Measurement
- Place:
- Salvador, Bahia, BRAZIL
- Time:
- 04 June 2000 - 08 June 2000