DEVELOPMENT OF A NEW 400 KN·M TORQUE CALIBRATION MACHINE

Hans Jörg Fraiss, Lioba Stenner, Dirk Röske
Abstract:
This paper describes the development of a torque calibration machine, based on a reference system, with a measurement range up to 400 kN·m and a target expanded relative measurement uncertainty of 0.1 %. Several factors that have to be considered as contributing to the uncertainty of measurement are discussed. The paper deals with multi-disc couplings, reference transducers and other mechanical components that are used to implement this calibration system.
Keywords:
calibration machine, large torque, measurement uncertainty
Download:
IMEKO-WC-2015-TC3-039.pdf
DOI:
-
Event details
Event name:
XXI IMEKO World Congress
Title:

Measurement in Research and Industry

Place:
Prague, CZECH REPUBLIC
Time:
30 August 2015 - 04 September 2015