DRIFT OF NICKEL BASED MIMS THERMOCOUPLES AT TEMPERATURES ABOVE 1000°C: THE EFFECT OF THERMOCOUPLE DIAMETER |
|---|
| Michele Scervini |
- Abstract:
- In this work the drift of type K and type N MIMS thermocouples has been studied as a function of the thermocouple outer diameter in the temperature range 1000 - 1300°C. It is shown that type K and type N MIMS thermocouples drift significantly above 1000°C, the drift being more pronounced for smaller diameters. The data presented in this paper allows to compare the performance of type K and type N thermocouples at high temperatures over a wide temperature range and at different diameters.
- Keywords:
- thermocouple, drift, Type K, Type N, MIMS
- Download:
- IMEKO-WC-2015-TC12-260.pdf
- DOI:
- -
- Event details
- Event name:
- XXI IMEKO World Congress
- Title:
Measurement in Research and Industry
- Place:
- Prague, CZECH REPUBLIC
- Time:
- 30 August 2015 - 04 September 2015