ADAPTIVE CELL DETECTION BY APPLICATION OF ROC METHODOLOGY

Giampaolo E. D’Errico
Abstract:
Receiver operating characteristic (ROC) methodology is finalized to modelling and implementation of an adaptive detection process with application to cellular micrographs. Numerical examples are elaborated to illustrate how the performance of a cell recognition task can be modulated according as a 4-point rating scale of process dependability.
Keywords:
cell micrographs, ROC methodology, adaptive image thresholding