MEASUREMENT OF VIBRATION DISPLACEMENT IN NMR LOGGING WHILE DRILLING

Yubin Sun, Li Kong, Jingjing Cheng
Abstract:
The random vibration of the drill collar results in the additional attenuation to the NMR LWD signals, which will bring additional error in the process of T2 spectrum inversion. The determination of the displacement will help to recuperate the signals. This paper studied the property of the drill collar and proposed a scheme to determine the random vibration displacement which used two tri-axis vibration accelerometers and a two axis magnetometer. The simulation results and the shaking table test demonstrate that this scheme is effective and can be implemented in the instrument.
Keywords:
measurement, random vibration, displacement, NMR LWD
Download:
IMEKO-WC-2015-TC22-440.pdf
DOI:
-
Event details
Event name:
XXI IMEKO World Congress
Title:

Measurement in Research and Industry

Place:
Prague, CZECH REPUBLIC
Time:
30 August 2015 - 04 September 2015