RECONSTRUCTION OF RADIAL CATALYST CONCENTRATION DISTRIBUTION IN AN EXPERIMENTAL TYPE FCC RISER

Silvio B. Melo, Carlos C. Dantas, Emerson A. de O. Lima, Francisco P. M. Simões, Eric F. de Oliveira,Valdemir. A. dos Santos
Abstract:
A gamma ray tomographic reconstruction of catalyst concentration distribution in laboratory experiments is presented. The images are generated by gamma transition measurements in an experimental riser simulating flow experiments. The manual scanner is adequate for mapping radial catalyst concentration distribution under spatial resolution of 0.002 m and density resolution of 10 kg/m³.
Keywords:
gamma tomography, catalyst concentration, experimental riser
Download:
PWC-2006-TC7-012u.pdf
DOI:
-
Event details
Event name:
XVIII IMEKO World Congress
Title:

Metrology for a Sustainable Development

Place:
Rio de Janeiro, BRAZIL
Time:
17 September 2006 - 22 September 2006