Measuring Set including a Virtual Standards® Technology-Based Superimposed Ultrasonic Flow Meter |
|---|
| S. M. Yermishin, A. V. Lopatin, V. A. Dulev, N. A. Khoteev, P. G. Shabanov, A. B. Menshikov, A. V. Startsev |
- Abstract:
- A Virtual Standard® technology-based flow measuring set has been developed for liquid media Virtual Standard® technology is a universal technology for determining and introducing corrections in measuring device readings to reduce their errors. The set consists of a measuring module implemented as Vzliot-PR superimposed ultrasonic flow meter (basic accuracy = 1.3 % to 2 %) and a processing module i.e, digital computing device. The resulting accuracy of the flow measuring set is 0.25 % to 0.5 %.
- Keywords:
- Superimposed ultrasonic flow meter, reading corrections, measurement result ambiguity, virtual standard