HIGH ACCURACY ANGLE INDEXING TABLE |
|---|
| Tsukasa Watanabe, Hiroyuki Fujimoto |
- Abstract:
- National Metrology Institute of Japan studied the high precision angle indexing table. We used the principle that NPL reported the indexing accuracy 0.01" in 1984. We verified this principle using the angular primary standard of Japan and proved this principle can exceed 0.001" super-high angular precision.
- Keywords:
- angle, indexing table, standard
- Download:
- PWC-2006-TC14-024u.pdf
- DOI:
- -
- Event details
- Event name:
- XVIII IMEKO World Congress
- Title:
Metrology for a Sustainable Development
- Place:
- Rio de Janeiro, BRAZIL
- Time:
- 17 September 2006 - 22 September 2006