GAS SENSING USING PHOTOLUMINESCENCE FROM PHOSPHOR CONTAINED SILICA GEL

T. Katsumata, H. Aizawa, W. Takechi, K. Ito, S. Komuro, T. Morikawa
Abstract:
Variations in the photoluminescence (PL) spectra from porous silica gel containing the luminous organic pigments were evaluated before and after the exposure in the vapors of CHCl3. Peak intensity of PL from rhodamine and fluorescein contained silica gel vary with the concentration of pigment. Peak intensity of PL also varies after exposure in the organic vapors of CHCl3. Temperature dependences of PL intensity from rhodamine and fluorescein contained silica gel are also evaluated for sensor applications. The organic luminous pigments contained silica gel is suggested to be useful fluorescent sensor materials.
Keywords:
photoluminescence imaging, non-destructive evaluation, food
Download:
PWC-2006-TC19-013u.pdf
DOI:
-
Event details
Event name:
XVIII IMEKO World Congress
Title:

Metrology for a Sustainable Development

Place:
Rio de Janeiro, BRAZIL
Time:
17 September 2006 - 22 September 2006