FORCE TRACEABILITY MEASUREMENTS TO ACHIEVE 0.005 % BEST MEASUREMENT CAPABILITY |
|---|
| Hans W. Werner, Emil Harreus |
- Abstract:
- The increasing accuracy of force transducers and their calibration had two major effects: the chance to better extract the capability of a reference standard machine (compared to a formerly mixed evaluation of machine plus transducer) and on the other hand the need to build up reference standard machines capable to calibrate those high precision transducers. Using the experience of designing force transducers, of constructing calibration machines and of calibrating force within the German Calibration Service (DKD) since 1977 HBM decided to take the challenge. Two new dead-weight force reference standard machines of 2.5 kN and 25 kN have been built up and their best measurement capability of significantly better than 0.01 % has been verified by transfer transducers from HBM´s product range.
- Download:
- IMEKO-TC3-2002-019.pdf
- DOI:
- -
- Event details
- IMEKO TC:
- TC3
- Event name:
- Joint International Conference on Force, Mass, Torque, Hardness and Civil Engineering Metrology in the age of globalization
- Title:
18th Conference on Force, Mass and Torque (together with 8th HARDMEKO TC5 Conference on Hardness Measurement and 1st TC20 Conference on Civil Engineering Metrology)
- Place:
- Celle, GERMANY
- Time:
- 24 September 2002 - 26 September 2002