A SAMPLING METHOD FOR HIGH ACCURACY PHASE DIFFERENCE MEASUREMENT |
|---|
| N. Hlupic, J. Butorac |
- Abstract:
- Sampling methods are nowadays commonly accepted for measurements of various signals and here we present our achievements in measurement of pure sine wave at low frequencies (up to about 500 Hz), that is, measurement of phase difference between two sinusoids. Firstly, we briefly discuss the mathematical form of samples and its implications on the calculations needed to determine the phase difference. We continue with deep explanations of an alghoritm for very accurate calculation of one parameter of the measured signals, the most important one for phase difference calculation. At the end, we present results of real laboratory measurements as the final proof of declared accuracy.
- Keywords:
- phase difference, sampling, high accuracy
- Download:
- IMEKO-TC4-2001-004.pdf
- DOI:
- -
- Event details
- IMEKO TC:
- TC4
- Event name:
- TC4 Symposium 2001
- Title:
11th IMEKO TC4 Symposium on Trends in Electrical Measurements and Instrumentation (together with 6th IMEKO TC4 Workshop on ADC Modelling and Testing)
- Place:
- Lisbon, PORTUGAL
- Time:
- 13 September 2001 - 14 September 2001