ACCURACY PARAMETERS OF CIRCUITS WITH RESISTIVE SENSORS

Zygmunt L. Warsza, Adam Idzkowski
Abstract:
The novelty of this work is the analysis of accuracy measures and its visualization especially for two parameter measurements. The parameters of the resistance-to-voltage converters, i.e. different types of DC bridge-circuits with arbitrary variable resistive sensors (of relative resistance increments) and their accuracy measures are presented. Transfer coefficients, limited error and also standard uncertainty as the functions of relative increments of resistances are considered in a broad range for different types of supply and for different configurations of sensors.
Keywords:
converter, resistance bridge, error, uncertainty
Download:
IMEKO-WC-2015-TC4-159.pdf
DOI:
-
Event details
Event name:
XXI IMEKO World Congress
Title:

Measurement in Research and Industry

Place:
Prague, CZECH REPUBLIC
Time:
30 August 2015 - 04 September 2015