Phase Error Determination for the Wideband Resistive Voltage Divider

Jiangtao Zhang, Xianlin Pan, Ying Song, Qing He
Abstract:
A new design of resistive voltage divider with series-parallel connection has been built. A selfcalibration method has also been proposed to determine the phase angle errors of the resistive voltage divider. The phase angle displacement has been measured by means of sampling with a high-speed digitizer. The measurement has been done at frequencies from 10 kHz to 100 kHz to calibrate two RVDs with ratio of 100:1 and the measurement results are presented.
Keywords:
Phase angle errors, Resistive Voltage Divider (RVD), Buffer, Capacitive leakage, Loading errors
Download:
IMEKO-TC4-2016-34.pdf
DOI:
-
Event details
IMEKO TC:
TC4
Event name:
TC4 Symposium 2016
Title:

21st IMEKO TC4 Symposium on Measurements of Electrical Quantities (together with 19th TC4 International Workshop on ADC and DCA Modeling and Testing, IWADC)
"Understanding the World through Electrical and Electronic Measurement"

Place:
Budapest, HUNGARY
Time:
07 September 2016 - 09 September 2016