Skip to main content

Proceedings

9762 papers found

Liu Yingshuang

A Simple Method to Calculate the Standard Calibration Value of Differential Pressure Flow Transmitter

Differential pressure flow transmitter is one of the combination instruments with pneumatic instrument and electrical unit and usually used with standard orifice plate. It is an important instrument widely used by the industrial enterprises for energy measurement and trading settlement. Generally, the flow transmitter is calibrated by maintenance and verification personnel on site. During calibration, the flow value will be converted into differential pressure value. To calibrate a differential pressure flow transmitter, complicated calculation is required before the standard signal input...

tc9-2004 · TC9 · 2004 · Download
Liu Jianhua, Chen Guanghui

Research on Insert Double Venturi Tube Measuring Equipment

The essay herein analyses and compares the mainly existing problems for the measurement of the air flow that is of lower velocity and in large diameter duct. Through the wind tunnel test, the research is emphasized on the characteristics and mathematical model of the insert double ventrui tube and describes the structure, composition, erection, specialties and application of such tube and its advantages when applied in the measurement and control of assistant combustion air, cool air and coal air (blast furnace coal air, cokery coal air and converter coal air) of the heating furnaces in...

tc9-2004 · TC9 · 2004 · Download
Wang Bonian, Ye Zengming, Liu Zhihua, Xie Rongbo

Iterative Computations of Unkowns for pressure Differential Devices by Means of Secant Method

The secant method for solving nonlinear equation is used to calculate the unknown parameters of pressure differential devices. It is shown that the important advantages are needing only unique iterative equation without considering different unknows, easily to obtain convergent solutions without to calculate the derivatives which can not be finished for complex nonlinear equation, and yielding high precision solutions. The formulae of initial values and the example for showing the results are presented, the results are excellent.

tc9-2004 · TC9 · 2004 · Download
Wang Bonian, Wang Dongwei, Lu Deyue, Zhu Jiashun

Study on the Fitting Equations of Discharge Coefficient for Entrance Flowmeters

A general form of discharge coefficient for entrance flowmeters, c = c 0 - c 1 Re c 2 is suggested and used to fit the calibrating data successfully. The main problem concerns to solve a set of nonlinear sequations, which is solved by a series of solutions of linear equations. This fitting equations are valuable and suitable for some other flowmeters.

tc9-2004 · TC9 · 2004 · Download
Li Zhi, Wang Chi

On the Standardization of Elbow Flow Meters

Based on the operating principles of elbow flow meters, this paper states that the core of standardization of elbow flow meters is the standardization of hardware's structural dimension. On condition that the elbow flow meters' feature structural dimension parameters R/D are strictly kept the same, the flow coefficients of elbow flow meters with the same conduit diameter determined by experiments have good consistency. Comparison of the experimental results of several elbow flow meters with different conduit diameters shows that the flow coefficient increases as the conduit diameter...

tc9-2004 · TC9 · 2004 · Download
Yuan Pingfan, He Min, Ren Jia, Liu Chunyan

A New Portable Instrument for Orifice Geometric Parameters Measurement

According to statistics, about 90 % natural gas flow meters used in America and Canada are orifices. In China, the figure is approximately 85 %. As we know there are 8 geometric parameters primarily affect the orifice measurement performance. And in the past, some parameters can be measured by several large instruments in labs, but the others such as upstream edge radius cannot be given the quantitative value. It is only estimated by experiences. Now all of the values are obtainable due to the development of the new portable 8 geometric parameters measurement instrument, which make use of...

tc9-2004 · TC9 · 2004 · Download
Li Jinhai

Calibration of Flow Meter by Standard Meter Method and Evaluation of Uncertainty

Flow meter is calibrated by flow standard facilities by master meter method, is becoming trend of flow meter calibration method. The research of the calibration method and evaluation of uncertainty are focused in science field. This paper analyzes the influence facts of the process of calibration of flow meter by standard meter method around the calibration of turbine flow meter by standard turbine flow meter, establishes the mathematical model and give out the evaluation method and program of calibration uncertainty.The method was verified by test.

tc9-2004 · TC9 · 2004 · Download
Zhang Fuyuan, He Yan, Qiu Fengchun, Lai Zhongze

Mobile Flow Working Standard of Ultrasonic Meter for Natural Gas

The components and testing results of working standard equipment for natural gas flow meter used multi-path ultrasonic meters in this paper. The testing results in different conditions by NMi of Netherlands, PTB of Germany and CVB of China showed that the uncertainties of the DN100 and DN300 meters for the standard equipment could meet the requirement of 0.5 % and 0.35 % respectively

tc9-2004 · TC9 · 2004 · Download
Liu Yanjun, Han Yizhong, Zhang Baozhu

Fuel Oil Dynamic Flow Standard Device and Its Application

This paper introduced a piston-type dynamic flow standard device and the method for applying step flow rate to the turbine flowmeter. Setting up math model of the turbine flowmeter and analyzing the dynamic parameter (step response time constant) and things that affect dynamic performance of the flowmeter in theory. Acquiring the step flow response data of the flowmeter by experiment and calculating the time constant. The reality result is consistent with theory.

tc9-2004 · TC9 · 2004 · Download
Valter Yoshihiko Aibe

What If the Calculated Uncertainty of a Calibrated Instrument is Lower than the Standard Instrument Uncertainty?

In the uncertainty of measurement evaluation it is essential a solid grasp of the physical and mathematical theory underlying the measurement model to make a sensible analysis of the experimental data. There may occur particular situations, which lead to results in apparent contradiction to our usual understanding of error analysis. This paper presents a detailed case of such situations arising in a flow meter calibration model.